 26. Place the Output Switch on the Remote Control
Box in the “OFF” Position.
 27. Turn all switches on the Remote Control Box to
“OFF” position. (i.e. Machine and Output)
CALIBRATION PROCEDURES
 28. For ULV calibration, carry out steps 1-22.
 29. Place Function Selector Dial in the #2 position.
Adjust flow rate to desired flow (4 oz, 6 oz, 8 oz,
etc.).
 30. Place Solenoid Switch on Remote Control Box to
“SPRAY” position.
 31. Place HIGH/LOW Selector Switch in the “HIGH”
position.
 32. Disconnect ¼ inch formulation line from the “T” on
the Spray Boom and place into a “pesticide only”
receptacle. Always use a suitable collection
container for pesticide measurement.
 33. Place the Output Switch on the Remote Control in
the “ON” position (fluid will begin to flow).
 34. Adjust the Flow Rate Knob on the Remote Control
Box to the desired rate.
 35. The timing person signals the beginning and the
end of the one (1) minute collection period.
Zobrazit stránku 147