DOD SR400D Specifikace Strana 150

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 244
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 149
142
PERFORMANCE CHECKLIST FOR THE
CURTIS MODEL 2952 ULV SPRAYER
TESTING OF ENVIRONMENTAL CONDITIONS
FOR ULV APPLICATIONS
A. Check the weather conditions expected during the
spray operations. REMEMBER, YOU SHOULD
NOT CONDUCT ULV OPERATIONS IN THE RAIN
OR IN STRONG WINDS.
B. Check for a temperature inversion. A temperature
in- version has occurred when the air temperature at
six feet above the ground is at least one degree
warmer than the ground temperature (This situation
usually occurs in the early morning and late evening
hours).
C. Check the wind speed by using a wind-measuring
device. The indicated wind speed should fall
between 4-6 mph and should be blowing across the
intended target area.
SETUP PROCEDURES
 1. Place the ULV on a truck or trailer and secure it for
towing.
 2. Check the fuel level. Add regular unleaded gas as
needed to the large red polyethylene tank.
Zobrazit stránku 149
1 2 ... 145 146 147 148 149 150 151 152 153 154 155 ... 243 244

Komentáře k této Příručce

Žádné komentáře